Search results for "Building Integrated Photovoltaic"

showing 6 items of 6 documents

ARCHITECTURE AND PHOTOVOLTAICS. Strategies, technologies and novel components for the building envelope

Il principale obiettivo della tesi ha riguardato lo studio di strategie e tecnologie per l’integrazione del fotovoltaico negli edifici, con particolare attenzione verso le tecnologie solari di terza generazione, e la successiva definizione di un componente multifunzionale innovativo per l’involucro edilizio integrato con Dye-sensitized Solar Cells (DSC). Nella prima parte del lavoro, la ricerca si è concentrata sull’analisi del mercato del Building Integrated Photovoltaics (BIPV), sottolineando differenze, limiti e potenzialità di ciascuna tecnologia fotovoltaica. Particolare attenzione, inoltre, è stata rivolta a un numero consistente di casi studio, ossia edifici di nuova costruzione o in…

Building Integrated Photovoltaics (BIPV)Glass BlockBuilding EnvelopeSettore ICAR/10 - Architettura TecnicaEnergy-efficient buildingBuilding technology
researchProduct

Mechanical Tests on Innovative BIPV Façade Components for Energy, Seismic, and Aesthetic Renovation of High-Rise Buildings

2018

The paper shows the results of mechanical tests carried out on prototypes of a new Building Integrated Photovoltaic (BIPV) component developed by the author and SBskin Smart Building Skin s.r.l. This patented innovative component is able to merge structural function, insulation proprieties, and production of clean energy for retrofit actions and/or the construction of translucent fa&ccedil

Engineering020209 energyGeography Planning and DevelopmentTJ807-830Settore ICAR/10 - Architettura Tecnica02 engineering and technologyManagement Monitoring Policy and Law010402 general chemistryTD194-19501 natural sciencesRenewable energy sourcesPrecast concreteinnovative product0202 electrical engineering electronic engineering information engineeringGE1-350translucent panelenergy efficiencyBuilding automationBIPV (Building Integrated Photovoltaic)Environmental effects of industries and plantsRenewable Energy Sustainability and the Environmentbusiness.industryPhotovoltaic systemhigh-rise buildingdry-assembly systemStructural engineeringmultifunctional component0104 chemical sciencesRenewable energybuilding envelopeEnvironmental sciencesFacadefaçadeBuilding-integrated photovoltaicsmechanical resistancebusinessBuilding envelopeEfficient energy use
researchProduct

Energy Optimization of BIPV Glass Blocks: a Multi-software Study

2017

Abstract The aim of this paper is to show the results of the performance analyses carried out on four patented glass block configurations integrated with third-generation Dye-sensitized Solar Cell (DSC) modules. The analyses take into account the thermal, optical and electrical performance by using three different software (COMSOL Multiphysics, WINDOW, Zemax), also enabling to take into consideration the peculiar three-dimensional geometry of this innovative glazed product. Starting from these results, new configurations improved as for the thermal insulation, are also introduced and studied, in order to make further considerations about the applicability of this building component for the …

Engineering020209 energyMultiphysics0211 other engineering and technologiesMechanical engineeringSettore ICAR/10 - Architettura Tecnica02 engineering and technologyGlass BlockSoftwareEnergy(all)Thermal insulationComponent (UML)021105 building & construction0202 electrical engineering electronic engineering information engineeringDye-sensitized Solar Cells (DSC)ZemaxBlock (data storage)Thermal and optical analysebusiness.industryStructural engineeringBuilding envelopeEnergy (all)Building Integrated PhotovoltaicBuilding-integrated photovoltaicsbusinessBuilding envelope
researchProduct

Photovoltaic facade: Comparison of actual technologies

2017

This article aims to establish the economic contribution of a photovoltaic system placed on a façade of a building, replacing traditional elements such as windows and glass-cement walls with active elements. The aim is to compare the behavior of next-generation systems, which favor architectonical integration, with traditional ones. Two novel systems have been taken into account: a dye sensitized solar cell (DSSC) and blue and grey thin film silicon panels. Different generation systems have been tested and compared in terms of efficiency and fill factor.

Materials scienceSilicon020209 energyPhotovoltaic systemEnergy Engineering and Power Technologychemistry.chemical_elementbuilding integrated photovoltaic02 engineering and technologySettore ING-INF/01 - ElettronicaEngineering physicsDye-sensitized solar cellchemistryPhotovoltaic module0202 electrical engineering electronic engineering information engineeringEconomic contributionFacadeFill factorDSSCElectrical and Electronic EngineeringThin filmthin film silicon2017 IEEE International Telecommunications Energy Conference (INTELEC)
researchProduct

ARCHITETTURA E FOTOVOLTAICO: STRATEGIE E CRITERI D’INTEGRAZIONE. ARCHITECTURE AND PHOTOVOLTAICS: STRATEGIES AND INTEGRATION CRITERIA

2016

Nonostante i numerosi esempi positivi offerti dal panorama architettonico degli ultimi due decenni, alcuni studi hanno dimostrato come esistano ancora delle barriere che limitano l’impiego del fotovoltaico (FV) negli edifici e come spesso queste riguardino aspetti legati all’accettazione delle soluzioni utilizzate, specialmente sul piano della qualità architettonica. Il presente lavoro descrive e analizza alcuni dei numerosi esempi di nuova costruzione o retrofit, nei quali il FV diventa parte integrante del processo progettuale, non solo per gli aspetti concernenti la produzione di energia ma anche per quelli propriamente legati alla funzionalità dell’involucro edilizio, all’efficienza ene…

Settore ICAR/10 - Architettura TecnicaBuilding Integrated Photovoltaics (BIPV) Architecture Sustainable Design Photovoltaics
researchProduct

Integrazione di celle solari di terza generazione nel vetromattone per la realizzazione di involucri edilizi traslucidi fotovoltaici

2013

L’integrazione di celle solari di terza generazione - Dye-sensitised Solar Cells (DSSC) - nel vetromattone consente di ottenere un prodotto edilizio in grado di generare energia pulita, personalizzabile in termini di colore, livelli di trasparenza e fi niture, adatto alla realizzazione di componenti edilizi fotovoltaici, traslucidi e multifunzionali, facilmente integrabili nelle chiusure degli edifi ci per la costruzione di involucri edilizi energeticamente effi cienti ed attivi anche in contesti climatici avversi, quali possono essere quelli del Mediterraneo e delle aree subtropicali. L’articolo illustra 4 differenti ipotesi di integrazione delle DSSC nel vetromattone fornendo, per ciascun…

Settore ICAR/10 - Architettura TecnicaInvolucri Edilizi Traslucidi Vetromattone Celle solari a colorante Fotovoltaico integrato negli edificiTranslucent Building Envelope Glassblock Dye-sensitize Solar Cell Building Integrated Photovoltaic
researchProduct